摘要
Atransformertypeironcoresnubber,asaprotectivedeviceagainstthestraycapacitanceduringthebreakdowninEAST,isanalyzedindetail.Threekindsoftopologyarepresented.Thenwiththeanalysisforequivalentcircuit,therangesofthreekeyparameters,i.e.,secondarysideresistance,leakageinductanceandsnubberinductance,aredetermined.Byconsideringthesaturationofthemagneticmaterial,adesignprincipleisalsopresented.Anearly1:10coresnubberistested.Itisprovedthatahighpermeabilitycorewithsecondaryresistorcanrestrainthedischargecurrenteffectively.
出版日期
2011年01月11日(中国Betway体育网页登陆平台首次上网日期,不代表论文的发表时间)